Recommended Lighting Levels
|
IESNA Lighting Handbook
|
Type of activity |
Lighting |
Public spaces with dark surroundings |
30 Lux
|
Simple orientation for short temporary visits |
50 Lux |
Working spaces where visual tasks are only occasionally performed |
100 Lux |
Performance of visual tasks of high contrast or large scale |
300 Lux |
Performance of visual tasks of medium contrast or small size |
500 Lux |
Performance of visual tasks of low contrast or very small size |
1000 Lux |
Performance of visual tasks near threshold of person’s ability to recognize an image |
3000-10000 Lux |
Industries Recommended Levels of Illumination |
Area And Task |
Lux Level |
Paper Manufacturing |
|
Beaters, grinding |
30 |
Finishing, cutting |
50 |
Hand Counting |
70 |
Paper machine reel, inspection |
100 |
Rewinder |
150 |
Warehousing, Storage |
|
Inactive |
5 |
Active: |
|
Rough Bulky |
10 |
Medium |
20 |
Fine |
50 |
Clothing Manufacture |
|
Receiving, storing, shipping, winding, measuring |
30 |
Pattern making, trimming |
50 |
Shops, making |
100 |
Textile Mills – Cotton |
|
Opening, mixing, picking |
30 |
Carding and drawing |
50 |
Slubbing, roving, spinning, spooling |
50 |
Beaming and splashing on combo Gray goods |
50 |
Denims |
150 |
Inspection |
|
Gray goods (hand tuning) |
150 |
Denims (rapid moving) |
500 |
Automatic tying-in |
150 |
Weaving |
100 |
Drawing-in by hand |
200 |
Machine Shops |
|
Rough bench and machine work |
50 |
Medium bench and machine work, ordinary automatic machines, rough grinding medium buffing and polishing |
100 |
Fine bench and machine work, fine automatic machines, medium grinding, fine buffing and polishing |
500 |
Extra-Fine bench and machine work, grinding fine work |
1000 |
Recommended Lighting Levels |
International Standard Serial Number ISSN: 2278-6252 |
Area/task/ process |
Illuminance (lux) |
Exterior circulating, walkways, stores, main entrances and exit roads, car parking, internal factory roads etc. |
20-50 |
Boiler house, transformer yards, furnace rooms, entrances, corridors, stairs etc. |
70-100 |
Circulation areas in industry, stores and stock rooms, canteen |
100-150 |
Coarse work |
200-300 |
Medium work |
300-500 |
Fine work |
500-1500 |
Very fine minute and precise work |
1500-3000 |
Bale breaking, washing , Stock dyeing, tinting, Mixing, Blowing |
200-300 |
Carding, drawing, roving |
300-500 |
Spinning, doubling, reeling, winding |
300-750 |
Warping |
300-400 |
Sizing |
400-500 |
Heading (drawing in) |
750-1000 |
Weaving (plain gray fabrics) |
200-300 |
Weaving (light colored) |
300-750 |
Weaving (dark colored) |
500-1000 |
Knitting |
300-750 |
Dyeing |
200- 450 |
Calendaring, chemical treatment |
300-750 |
Grey cloth inspection |
700-1000 |
Final inspection |
1000-2000 |
Recommended lighting levels |
IESNA Lighting Handbook |
Type of activity |
Lighting (Lux) |
Public spaces with dark surroundings |
30 |
Simple orientation for short temporary visits |
50 |
Working spaces where visual tasks are only occasionally performed |
100 |
Performance of visual tasks of high contrast or large scale |
300 |
Performance of visual tasks of medium contrast or small size |
500 |
Performance of visual tasks of low contrast or very small size |
1000 |
Performance of visual tasks near threshold of person’s ability to recognize an image |
3000-10000 |
Illuminance Values for Indoor Activities |
TABLE 10.4 IES |
ACTIVITY |
CATEGORY |
LUX |
Public spaces with dark surroundings |
large area (lobby space) |
20-30-50 |
Simple orientation for short temporary visits |
large area (lobby space) |
50-75-100 |
Working spaces where visual tasks are only occasionally performed |
large area (lobby space) |
100-150-200 |
Performance of visual tasks of high contrast or large size |
localized tasks |
200-300-500 |
Performance of visual tasks of medium contrast or small size |
localized tasks |
500-750-1000 |
Performance of visual tasks of low contrast or very small size |
localized tasks |
1000-1500-2000 100 |
Performance of visual tasks of low contrast or very small size over a prolonged period |
extremely difficult visual tasks |
2000-3000-5000 |
Performance of very prolonged and exacting visual tasks |
extremely difficult visual tasks |
5000-7500-10000 |
Performance of very special visual tasks of extremely low contrast |
extremely difficult visual tasks |
10000-15000-20000 |
Lighting levels-Sports |
Sports |
Illumination |
Football/Rugby |
|
National/ international |
500 Lux |
Regional/Local |
200 Lux |
Local/Training |
75 Lux |
Tennis |
|
National/ international |
500 Lux |
Regional/Local |
300 Lux |
Local/Training |
200 Lux |
Equestrian |
|
National/ international |
500 Lux |
Regional/Local |
200 Lux |
Local/Training |
100 Lux |
Badminton |
|
National/ international |
750 Lux |
Regional/Local |
500 Lux |
Local/Training |
300 Lux |
Court lighting |
|
Social Play |
310 Lux |
Club Competition |
435 Lux |
International |
1250 Lux |
Swimming |
|
National/Internal |
750 Lux |
Regional/Local |
500 Lux |
Local/Training |
200 Lux |
Lighting levels-Sports |
Australian Standard AS 2560.2.6 – 1994 |
Sport |
Illumination Level |
Baseball |
|
Baseball (International & National) |
1500 lux |
Baseball (AAA Standard) |
750 lux |
Baseball (Club Competition) |
250 lux |
Football |
|
Recreational Level |
50 lux |
Amateur Level (Training) |
50 lux |
Amateur Level (Competition) |
100 lux |
Semi-Professional level (Training) |
50 lux |
Semi-Professional (match Practice) |
100 lux |
Semi-Professional (Competition) |
200 lux |
Professional level (Training) |
100 lux |
Professional level (Match practice) |
200 lux |
Professional level (Competition) |
500 lux |
For all sports the minimum for TV coverage. |
1500 lux |
Recommended Lighting Levels For Sports Areas |
Area Type |
Lux |
Archery, indoor |
|
General Area |
25 |
Shooting Zone |
50 |
Target (Vertical) |
100 |
Badminton |
|
Recreational |
300 |
Supervised Training |
400 |
Club & County |
400 |
National & International |
500 |
Bowls, indoor |
|
Practice |
300 |
Club & County |
400 |
National & International |
500 |
Boxing |
|
Club & Supervised Training |
500 |
Regional |
750 |
National |
1000 |
International |
2000 |
Special Events |
2000 |
Cricket, indoor |
|
Recreational & Supervised Training |
400 |
Club & County |
500 |
Cycle Racing, |
|
Training |
300 |
Club |
500 |
National & International |
750 |
Equestrian, indoor |
|
Practice & Training, show jumping |
400 |
Practice & Training, Dressage |
300 |
Competition Show Jumping |
700 |
Competition Dressage) |
500 |
Five-A-Side Football, indoor |
|
Recreational & Supervised Training |
300 |
Club & County |
400 |
National & International |
500 |
Handball, indoor |
|
Recreational & Supervised Training |
300 |
Club |
400 |
County & National |
500 |
International |
750 |
Hockey, indoor |
|
Recreational & Supervised Training |
300 |
Club |
400 |
County & National |
500 |
International |
750 |
Ice Rinks, Indoor |
|
Hockey & Figure Skating Training |
200 |
Hockey & Figure Skating Competition |
750 |
Skating, Recreational |
100 |
Lawn Tennis, indoor |
|
Recreational |
300 |
Practice & Club |
400 |
County |
500 |
National & International |
750 |
Lawn Tennis, outdoor |
|
Recreational |
200 |
Club |
300 |
County |
400 |
National & International |
500 |
Martial Arts, indoor |
|
Supervised Training |
300 |
Club |
400 |
National |
500 |
Netball, indoor |
|
Recreational & Supervised Training |
300 |
Club & County |
400 |
National & International |
500 |
Shooting, indoor |
|
Target (Vertical) |
1000 |
Shooting Zone |
300 |
Snooker & Billiards |
|
Recreational & Club |
750 |
National & International |
1000 |
Squash |
|
Recreational & Supervised Training |
300 |
Club & County |
400 |
indoor National |
500 |
International |
750 |
Swimming, indoors |
|
Recreational |
200 |
Club & County |
300 |
National |
500 |
International |
10000 |
Table Tennis |
|
Recreational |
200 |
Club & County |
300 |
National |
500 |
International |
750 |
Volleyball |
|
Recreational |
200 |
Training, Club & County |
300 |
National |
500 |
International |
750 |
Weight Training |
|
Supervised Training |
400 |
Sports Halls |
|
Recreational |
300 |
Club & County |
400-500 |
National & International |
500-750 |
Televised (vertical/normal to camera) |
1000-2000 |
Indoor Arenas |
|
Maintenance of Area |
100 |
General Lighting & Training |
300 |
Competition |
500 |
Spectator Viewed Events |
900 |
Televised (vertical/normal to camera) |
1000-2000 |
February 01, 2019 at 08:00AM by Department of EEE, ADBU: http://bit.ly/2AyIRVT